Skip to content

BMS Electrical Notes

  • Battery Voltage: 24V

  • Cells: P42A
    Also see the Batemo Model for this cell

Standby/Shutoff Currents

copy from Notion - BMS C.1

According to the following table, the idle current is assumed to be somewhere around 110 µA, which is well within the requirements. Note that this is a worst-case estimate, modeling the buck converter as linear regulator.

Part Designator Current Net Comment
INA180A4 U7 80 µA 5V input bias current (total or per input?)
BQ76200 U6 10 µA BAT+
STM32 U1 < 10 µA VCC shutdown mode, RTC active, LSE in high drive mode (?)
R 1M 1% 0402 R16 3.3 µA VCC 3V3 net EN pull-up resistor
LMR36502 U9 1.5 µA BAT+ 5V Buck regulator
BQ76925 U2 1.5 µA BAT+ analog frontend
PMZB1200UPEYL Q11 1 µA VCC drain leakage current
PMZB1200UPEYL Q8 1 µA BAT+ drain leakage current
NX7002BKMB Q9 1 µA BAT+ drain leakage current
BZX585-B27 D11 50 nA BAT+ hold-up circuit clamping zener diode
TPS7A0233 U11, U13 25 nA 5V
PTVS54VS1UR D13 1 nA BAT+ BAT+/BAT- TVS diode